Technical Data:
Technical Data
For Castings Design Reference
1. Linear
Tolerance (mm)
|
Casting
Dimension (mm) |
10 |
10~25 |
25~50 |
50~75 |
75~100 |
100~150 |
150~200 |
200~250 |
>250 |
|
Normal
Tolerance (mm) |
0.15 |
0.25 |
0.35 |
0.50 |
0.65 |
1.00 |
1.50 |
1.80 |
1.00% |
|
Special
Tolerance (mm) |
0.10 |
0.15 |
0.25 |
0.40 |
0.50 |
0.75 |
1.00 |
1.20 |
0.60% |
2. Tolerance
for Flatness, Straightness and Roundness
|
Castings Dimension (mm) |
0~25 |
25~50 |
50~100 |
100~150 |
|
Tolerance (mm) |
0.2 |
0.4 |
0.6 |
0.8 |
3.Surface Roughness (Ra/um)
4.Limit Dimension for Cast
Holes and Slots
|
Items |
Diameter
(Ø
mm) |
L
/ D |
|
|
Ø2~Ø3 |
L
/ D
1 |
|
Ø4~Ø7 |
L
/ D 2 |
|
Ø8 |
L
/ D
2.5 |
|
 |
Ø2~Ø3 |
L
/ D
2 |
|
Ø4~Ø7 |
L
/ D
4 |
|
Ø8 |
L
/ D
5 |
5.Size and Weight Range
|
Items |
Max |
Min |
Best |
|
Outline Dimension (mm) |
1000x300x300 |
20x10x10 |
<150x100x100 |
|
Weight (Kg) |
40 |
0.015 |
0.2~1.5 |
|
Thickness of Wall (mm) |
-- |
1.0 |
5~10 |
6. Proposal for Construction Design
|